This product is part of Smart Relay - Zelio Logic SR2/SR3, an offer of simple automation systems from 10 to 40 I/Os. This Zelio Logic compact smart relay features 20 I/Os, 0 to 240 with ladder and 0 to 500 with FBD programming control scheme lines. It is a module with rated supply voltage of 24V AC and cycle time of 6ms to 90ms. It offers 12 discrete inputs with voltage of 24V AC and 4 relay outputs with voltage range from 24V to 250V AC and 5V to 30V DC. It is an IP20 and IP40 rated product. It weighs 0.35kg. The main application of this module is industry and building/service sector. This product is certified by C-Tick, GL, UL, CSA and GOST. It meets EN/IEC 60068-2-6 Fc and EN/IEC 61000-4-11 standards. Easy to use, Zelio Logic provides a real alternative solutions based on cabled logic or specific cards.
| |
Width: | 124.600 mm |
Height: | 90.000 mm |
Depth: | 59.500 mm |
Expandable: | false |
Switching current: | 8.000 A |
With time switch clock: | true |
With display: | false |
Suitable for safety functions: | false |
Number of digital inputs: | 12.000 |
Number of digital outputs: | 8.000 |
Number of analogue inputs: | 0.000 |
Number of analogue outputs: | 0.000 |
Voltage type of supply voltage: | AC/DC |
Supporting protocol for LON: | false |
Number of HW-interfaces industrial Ethernet: | 0.000 |
Number of HW-interfaces RS-232: | 1.000 |
Number of HW-interfaces RS-422: | 0.000 |
Number of HW-interfaces RS-485: | 0.000 |
Number of HW-interfaces serial TTY: | 0.000 |
Number of HW-interfaces USB: | 0.000 |
Number of HW-interfaces parallel: | 0.000 |
Number of HW-interfaces other: | 1.000 |
With optical interface: | false |
Supporting protocol for TCP/IP: | false |
Supporting protocol for ASI: | false |
Supporting protocol for PROFIBUS: | false |
Supporting protocol for CAN: | false |
Supporting protocol for INTERBUS: | false |
Supporting protocol for KNX: | false |
Supporting protocol for Modbus: | false |
Supporting protocol for Data-Highway: | false |
Supporting protocol for DeviceNet: | false |
Supporting protocol for SUCONET: | false |
Supporting protocol for other bus systems: | false |
Redundancy: | false |
With relay output: | true |
Rail mounting possible: | true |
Explosion safety category for gas: | None |
Explosion safety category for dust: | None |
Appendant operation agent (Ex ia): | false |
Appendant operation agent (Ex ib): | false |
Degree of protection (IP): | IP20 |
Supporting protocol for SERCOS: | false |
Supporting protocol for INTERBUS-Safety: | false |
Number of interfaces PROFINET: | 0.000 |
Number of HW-interfaces Wireless: | 0.000 |
Front built-in possible: | true |
Rack-assembly possible: | false |
Wall mounting/direct mounting: | true |
Expansion device: | false |
Radio standard Bluetooth: | false |
Radio standard Wi-Fi 802.11: | false |
Basic device: | true |
IO link master: | false |
Performance level according to EN ISO 13849-1: | None |
Supporting protocol for AS-Interface Safety at Work: | false |
Supporting protocol for DeviceNet Safety: | false |
Supporting protocol for EtherNet/IP: | false |
Supporting protocol for Foundation Fieldbus: | false |
Supporting protocol for PROFINET CBA: | false |
Supporting protocol for PROFINET IO: | false |
Supporting protocol for PROFIsafe: | false |
Supporting protocol for SafetyBUS p: | false |
Supply voltage AC 50 Hz: | 24.000 V |
Supply voltage AC 60 Hz: | 24.000 V |
Radio standard GPRS: | false |
Radio standard GSM: | false |
Radio standard UMTS: | false |
SIL according to IEC 61508: | None |