This Acti 9 Smartlink SI B is a Modbus Master TCP/IP and Wireless smart communication module with 7 channels and 1 analog input. It communicates with the auxiliaries iACT24 for iCT contactors, iATL24 for iTL impulse relays, iOF+SD24 for iC60, iID, ARA, RCA & iSW-NA. It can master up to 8 Acti 9 SmartLink ModBus or other ModBus slaves connected thanks to the RS485 Modbus connector. It is used to transfer data from Acti 9 devices to a PLC or network monitoring system thanks to the RJ45 Ethernet connector. It communicates also with OF+SD24 for C60, C120, DPN, ID & C60H-DC, Ti24 for RCA iC60 & Reflex iC60. It can associated upto 20 PowerTag energy sensors with radiofrequency communication. It is supplied with1 power supply connector 24VDC, 2 bolts for mounting on Linergy FM80. The link is Ethernet 10/100MB. The transfer rate is self-adaptable from 9600 to 19200 baud. The Modbus addresing range is 1 to 247. It is a 4-pin connector type of bus. The It is a plug-in connection. The maximum le
| |
Width: | 359.000 mm |
Height: | 23.000 mm |
Depth: | 40.000 mm |
Input current at signal 1: | 2.500 mA |
Suitable for safety functions: | false |
Number of digital inputs: | 14.000 |
Number of digital outputs: | 7.000 |
Number of analogue inputs: | 2.000 |
Number of analogue outputs: | 0.000 |
Voltage type of supply voltage: | DC |
Supporting protocol for LON: | false |
Number of HW-interfaces industrial Ethernet: | 1.000 |
Number of HW-interfaces RS-232: | 0.000 |
Number of HW-interfaces RS-422: | 0.000 |
Number of HW-interfaces RS-485: | 1.000 |
Number of HW-interfaces serial TTY: | 0.000 |
Number of HW-interfaces USB: | 0.000 |
Number of HW-interfaces parallel: | 0.000 |
Number of HW-interfaces other: | 0.000 |
With optical interface: | false |
Type of voltage (input voltage): | DC |
Supporting protocol for TCP/IP: | true |
Supporting protocol for ASI: | false |
Supporting protocol for PROFIBUS: | false |
Supporting protocol for CAN: | false |
Supporting protocol for INTERBUS: | false |
Supporting protocol for KNX: | false |
Supporting protocol for Modbus: | true |
Supporting protocol for Data-Highway: | false |
Supporting protocol for DeviceNet: | false |
Supporting protocol for SUCONET: | false |
Supporting protocol for other bus systems: | false |
Output voltage at digital output: | 24.000 V |
Output current at digital output: | 0.100 A |
Analogue input, current: | true |
Analogue input, voltage: | true |
Analogue input, resistor: | true |
Analogue input, resistor temperature: | false |
Analogue input, thermocouple: | false |
Analogue input signal configurable: | true |
Short-circuit protection, digital outputs available: | true |
Resolution of the analogue inputs: | 12.000 Bit |
Type of digital output: | Other |
Type of electric connection: | Plug-in connection |
Rail mounting possible: | false |
Explosion safety category for gas: | None |
Explosion safety category for dust: | None |
Fieldbus connection over separate bus coupler possible: | false |
System accessory: | true |
Appendant operation agent (Ex ia): | false |
Appendant operation agent (Ex ib): | false |
Degree of protection (IP): | IP20 |
Supporting protocol for SERCOS: | false |
Supporting protocol for INTERBUS-Safety: | false |
Number of interfaces PROFINET: | 0.000 |
Number of HW-interfaces Wireless: | 1.000 |
Front built-in possible: | false |
Rack-assembly possible: | false |
Wall mounting/direct mounting: | true |
Radio standard Bluetooth: | false |
Radio standard Wi-Fi 802.11: | false |
IO link master: | false |
Performance level according to EN ISO 13849-1: | None |
Supporting protocol for AS-Interface Safety at Work: | false |
Supporting protocol for DeviceNet Safety: | false |
Supporting protocol for EtherNet/IP: | false |
Supporting protocol for Foundation Fieldbus: | false |
Supporting protocol for PROFINET CBA: | false |
Supporting protocol for PROFINET IO: | false |
Supporting protocol for PROFIsafe: | false |
Supporting protocol for SafetyBUS p: | false |
Supply voltage DC: | 24.000 V |
Permitted voltage at input: | 19.200 V | 28.800 V |
Type of output voltage: | DC |
Digital inputs configurable: | true |
Analogue inputs configurable: | true |
Analogue outputs configurable: | false |
Digital outputs configurable: | true |
Radio standard GPRS: | false |
Radio standard GSM: | false |
Radio standard UMTS: | false |
SIL according to IEC 61508: | None |