This Zelio Logic SR2 compact smart relay / programmable controller uses a supply voltage of 24V direct current. It has 10 inputs / outputs with screw-clamp terminals and has an integrated LCD display. It has compact design, allowing installation on DIN rail. It also offers simple programming, display and diagnosing of malfunctions display and navigation buttons. Its simple ladder programming makes it adapted for non-specialists.
| |
Width: | 71.200 mm |
Height: | 90.000 mm |
Depth: | 59.500 mm |
Expandable: | false |
Switching current: | 8.000 A |
With time switch clock: | false |
With display: | true |
Suitable for safety functions: | false |
Number of digital inputs: | 6.000 |
Number of digital outputs: | 4.000 |
Number of analogue inputs: | 0.000 |
Number of analogue outputs: | 0.000 |
Voltage type of supply voltage: | DC |
Supporting protocol for LON: | false |
Number of HW-interfaces industrial Ethernet: | 0.000 |
Number of HW-interfaces RS-232: | 1.000 |
Number of HW-interfaces RS-422: | 0.000 |
Number of HW-interfaces RS-485: | 0.000 |
Number of HW-interfaces serial TTY: | 0.000 |
Number of HW-interfaces USB: | 0.000 |
Number of HW-interfaces parallel: | 0.000 |
Number of HW-interfaces other: | 1.000 |
With optical interface: | false |
Supporting protocol for TCP/IP: | false |
Supporting protocol for ASI: | false |
Supporting protocol for PROFIBUS: | false |
Supporting protocol for CAN: | false |
Supporting protocol for INTERBUS: | false |
Supporting protocol for KNX: | false |
Supporting protocol for Modbus: | false |
Supporting protocol for Data-Highway: | false |
Supporting protocol for DeviceNet: | false |
Supporting protocol for SUCONET: | false |
Supporting protocol for other bus systems: | false |
Redundancy: | false |
With relay output: | true |
Rail mounting possible: | true |
Explosion safety category for gas: | None |
Explosion safety category for dust: | None |
Appendant operation agent (Ex ia): | false |
Appendant operation agent (Ex ib): | false |
Degree of protection (IP): | IP20 |
Supporting protocol for SERCOS: | false |
Supporting protocol for INTERBUS-Safety: | false |
Number of interfaces PROFINET: | 0.000 |
Number of HW-interfaces Wireless: | 0.000 |
Front built-in possible: | true |
Rack-assembly possible: | false |
Wall mounting/direct mounting: | true |
Expansion device: | false |
Radio standard Bluetooth: | false |
Radio standard Wi-Fi 802.11: | false |
Basic device: | true |
IO link master: | false |
Performance level according to EN ISO 13849-1: | None |
Supporting protocol for AS-Interface Safety at Work: | false |
Supporting protocol for DeviceNet Safety: | false |
Supporting protocol for EtherNet/IP: | false |
Supporting protocol for Foundation Fieldbus: | false |
Supporting protocol for PROFINET CBA: | false |
Supporting protocol for PROFINET IO: | false |
Supporting protocol for PROFIsafe: | false |
Supporting protocol for SafetyBUS p: | false |
Supply voltage DC: | 24.000 V |
Radio standard GPRS: | false |
Radio standard GSM: | false |
Radio standard UMTS: | false |
SIL according to IEC 61508: | None |