Panel Mount - UPD24TP Series. SIP SSR 3 output channels in one package with common control input Ratings per channel pf 15A @ 280 Vac Panel mount with quick connect terminals SCR output for heavy i...
Maximum Load Current = 25 A Mounting Type = Surface Mount Maximum Load Voltage = 1000 V Minimum Load Voltage = 1 V Minimum Control Voltage = 8 V dc Control Voltage Range = 8 → 16 V dc Minimum Load ...
Maximum Load Current = 25 A Mounting Type = Surface Mount Maximum Load Voltage = 1000 V Minimum Control Voltage = 20 V dc Control Voltage Range = 2028 V dc Minimum Load Current = 20 mA Terminal Typ...
C-UL-US listed AC output devices are TUV certified to EN 62314 Standard CE compliant to the low voltage and EMC Directives and to RoHS and China RoHS Directives. For the Thermal Pad for use with th...
Derating will limit the maximum load current at temperatures above 25 °C. UL, VDE. Models with internal overvoltage protection are not suitable for capacitive loads. Heat sink not included. For loa...
Derating will limit the maximum load current at temperatures above 25 °C. UL recognised component for Canada and US, VDE. Heat sink not included. For load current de-rating and heat sink details se...
Maximum Load Current = 90 A Mounting Type = Panel Mount Maximum Load Voltage = 660 V ac Minimum Load Voltage = 48 V ac Minimum Control Voltage = 4 V dc Switching Type = Zero Cross Control Voltage R...
Panel Mounting with Heatsink - HS053 Series. 82.5 amp AC output @ 40°C 3 phase output 3 to 32 Vdc input control voltage Panel mounted UL, CSA, VDE, CE approved SSRs Thermal pad installed
RoHS Compliant. Panel Mounting - LVD Series. The LVD Series from Crydom offers a panel mounting solid state relay within a compact package capable of handling 40A to 100A loads within a 3 → 75 Vdc ...
LS Series - SIL SSR 12A at 280Vac. These Crydom LS series SIL SSRs have a metal baseplate design for direct attachment of external heat sink to achieve maximum current ratings. The LS series SCR ou...
Derating will limit the maximum load current at temperatures above 25 °C. UL recognised component for Canada and US, VDE. Heat sink not included. For load current de-rating and heat sink details se...
Maximum Load Current = 75 A Mounting Type = Panel Mount Maximum Load Voltage = 530 V ac Minimum Load Voltage = 48 V ac Maximum Control Voltage = 280 Vrms Switching Type = Zero Cross Control Voltage...
Maximum Load Current = 7 A Mounting Type = Surface Mount Maximum Load Voltage = 60 V dc Minimum Load Voltage = 3 V dc Minimum Control Voltage = 3.5 V dc Switching Type = DC Control Voltage Range = ...
Derating will limit the maximum load current at temperatures above 25 °C. UL; CSA; VDE. Integral heatsink and DIN rail clip included. CMRD/A Series, 240/480/600Vac, ac O/P SSRs. Zero Voltage Switch...
Derating will limit the maximum load current at temperatures above 25 °C. UL; CSA; VDE. Integral heatsink and DIN rail clip included. CMRD/A Series, 240/480/600Vac, ac O/P SSRs. Zero Voltage Switch...
Maximum Load Current = 60 A Mounting Type = Surface Mount Maximum Load Voltage = 60 V dc Minimum Load Voltage = 1 V dc Minimum Control Voltage = 3.5 V dc Control Voltage Range = 3.5 → 32 V dc Minim...
UL, CE. Panel Mount - PowerPlus DC. Optically Isolated MOSFET output AC and DC control Easily paralleled for higher-current applications LED status indicator Optional IP20 cover (Manufacturer Part ...
UL. CMX-SIL SSR up to 10Adc. These MOSFET output solid state relays offer DC switching in a PCB style SIP package. Typically application is for the control of solenoid valves. They are also used to...
UL. CMX-SIL SSR up to 10Adc. These MOSFET output solid state relays offer DC switching in a PCB style SIP package. Typically application is for the control of solenoid valves. They are also used to...
Derating will limit the maximum load current at temperatures above 25 °C. UL; CSA; VDE. Integral heatsink and DIN rail clip included. CMRD/A Series, 240/480/600Vac, ac O/P SSRs. Zero Voltage Switch...
Maximum Load Current = 50 A rms Mounting Type = Surface Mount Maximum Load Voltage = 280 V ac Minimum Load Voltage = 24 V ac Maximum Control Voltage = 32 V dc Switching Type = Zero Cross Control Vo...
Derating will limit the maximum load current at temperatures above 25 °C. UL, VDE. Models with internal overvoltage protection are not suitable for capacitive loads. Heat sink not included. For loa...
Derating will limit the maximum load current at temperatures above 25 °C. UL, VDE. Models with internal overvoltage protection are not suitable for capacitive loads. Heat sink not included. For loa...
Derating will limit the maximum load current at temperatures above 25 °C. UL, VDE. Models with internal overvoltage protection are not suitable for capacitive loads. Heat sink not included. For loa...
Maximum Load Current = 50 A rms Mounting Type = Panel Mount Maximum Load Voltage = 530 V rms Minimum Control Voltage = 4 V Switching Type = Zero Cross Control Voltage Range = 3 → 32 V dc Minimum Lo...
CE, RoHS. Panel Mount - 53TP Series. Three-phase solid-state relay; ratings 25A , 50A per phase at 48-530 Vac Two package styles IP20 or IP00 SCR output for heavy industrial loads AC or DC control ...
Heat sink not included. For load current de-rating and heat sink details see manufacturers datasheet. MCBC- Burst Fire Controller. This device regulates the speed of an on/off pulse. Provides a smo...
Derating will limit the maximum load current at temperatures above 25 °C. UL, VDE. Models with internal overvoltage protection are not suitable for capacitive loads. Heat sink not included. For loa...
Derating will limit the maximum load current at temperatures above 25 °C. UL/cUL. Heat sink not included. For load current de-rating and heat sink details see manufacturers datasheet. Series PS Pea...
Derating will limit the maximum load current at temperatures above 25 °C. UL, VDE. Models with internal overvoltage protection are not suitable for capacitive loads. Heat sink not included. For loa...
Maximum Load Current = 50 A Mounting Type = Panel Mount Maximum Load Voltage = 660 V ac Minimum Load Voltage = 48 V ac Minimum Control Voltage = 4 V Switching Type = Zero Cross Control Voltage Rang...
C-UL-US listed AC output devices are TUV certified to EN 62314 Standard CE compliant to the low voltage and EMC Directives and to RoHS and China RoHS Directives. For the Thermal Pad for use with th...
Maximum Load Current = 50 A Mounting Type = Panel Mount Maximum Load Voltage = 530 V Maximum Control Voltage = 32 V Switching Type = Zero Cross Control Voltage Range = 3 → 32 V dc Minimum Load Curr...
Heat sink not included. For load current de-rating and heat sink details see manufacturers datasheet. MCPC - Phase Angle Controller. Phase angle controller/SSR in one package. Ideal for any soft st...
UL, CSA, VDE. CX Series SIL SSR, 5A at 12 to 660Vac. Exceptional surge rating and steady state rating of 5A ac Models to switch from 48-660Vrms 250A pk 1-cycle surge capability Input-Output capacit...
Derating will limit the maximum load current at temperatures above 25°C. MCX-SIL SSR up to 5Aac. AC or DC controlled versions Ultra high 1-cycle surge capability Surge current peak: 250A Input-Outp...
Derating will limit the maximum load current at temperatures above 25°C. MCX-SIL SSR up to 5Aac. AC or DC controlled versions Ultra high 1-cycle surge capability Surge current peak: 250A Input-Outp...
UL. CMX-SIL SSR up to 10Adc. These MOSFET output solid state relays offer DC switching in a PCB style SIP package. Typically application is for the control of solenoid valves. They are also used to...
UL. CMX-SIL SSR up to 10Adc. These MOSFET output solid state relays offer DC switching in a PCB style SIP package. Typically application is for the control of solenoid valves. They are also used to...
UL, CSA, VDE. CX Series SIL SSR, 5A at 12 to 660Vac. Exceptional surge rating and steady state rating of 5A ac Models to switch from 48-660Vrms 250A pk 1-cycle surge capability Input-Output capacit...
Derating will limit the maximum load current at temperatures above 25°C. MCX-SIL SSR up to 5Aac. AC or DC controlled versions Ultra high 1-cycle surge capability Surge current peak: 250A Input-Outp...
UL, CSA, VDE. CX Series SIL SSR, 5A at 12 to 660Vac. Exceptional surge rating and steady state rating of 5A ac Models to switch from 48-660Vrms 250A pk 1-cycle surge capability Input-Output capacit...
Derating will limit the maximum load current at temperatures above 25°C. MCX-SIL SSR up to 5Aac. AC or DC controlled versions Ultra high 1-cycle surge capability Surge current peak: 250A Input-Outp...
Maximum Load Current = 5 A Mounting Type = PCB Mount Maximum Load Voltage = 280 V ac Minimum Load Voltage = 12 V ac Maximum Control Voltage = 32 V Switching Type = Zero Cross Control Voltage Range ...
UL Recognised, CE and RoHS Compliant. Panel Mounting - EL Series. The EL Series from Crydom offers a panel mounting solid state relay within a compact package capable of handling 5A and 10A loads w...
UL Recognised, CE and RoHS Compliant. Panel Mounting - EL Series. The EL Series from Crydom offers a panel mounting solid state relay within a compact package capable of handling 5A and 10A loads w...
cUL, IEC, CE, CCC ; RoHS compliant. Plug In, DIN / PCB Mount - ED Series. The DC switching ED series from Crydom offers a DC output solid state relay series in an industry standard EMR plug in pack...
cUL, IEC, CE, CCC ; RoHS compliant. Plug In, DIN / PCB Mount - ED Series. The DC switching ED series from Crydom offers a DC output solid state relay series in an industry standard EMR plug in pack...
cUL, IEC, CE, CCC ; RoHS compliant. Plug In, DIN / PCB Mount - ED Series. The DC switching ED series from Crydom offers a DC output solid state relay series in an industry standard EMR plug in pack...
cUL, IEC, CE, CCC ; RoHS compliant. Plug In, DIN / PCB Mount - ED Series. The DC switching ED series from Crydom offers a DC output solid state relay series in an industry standard EMR plug in pack...